has not been reset than boiler will not start. The combustion of fossil fuels releases different byproducts of combustion. Troubleshooting Flame Failure - YouTube 0:00 / 1:10 Intro Troubleshooting Flame Failure Nortek Global HVAC 13.9K subscribers Subscribe 33K views 5 years ago These tips are for licensed HVAC. PDF TROUBLE SHOOTING SUGGESTIONSGAS, OIL OR GAS/OIL BURNER - Power Flame Application: Domestic Hot Water Heating. Your boiler is a critical piece of machinery, and your business often cannot continue in its absence, so you need to diagnose and repair any issues as quickly as possible. Flame scanners should be inspected and cleaned at least once per month. 1. I have no Manuals. Your flame scanner may operate via UV, visible, or infrared light signaling. If your boiler is failing to ignite, you are probably in a hurry to figure out why. If your boilers flame starts acting up, its important to troubleshoot the problem as soon as possible. Used many soot sticks but still giving alarm after every 3or 4hours.belt tightness also checked.Apms is okey.pls advise.regards, auto firing is ok, but when fire manually,fan is only running but no purging at all..our boiler is aalborg..tnx. Get Your FREE Electric Boiler Hire estimate in 3 easy steps. Solutions: For fly ash erosion, distribute flow evenly through the boiler and consider burning a lower ash fuel. Turn off your appliance by calling an emergency boiler repair company. Modulating valves are often used to control temperature at terminal units, air handling units, and steam to hot water heat exchangers. Any suggestions on why the striker on pilot would continue striking as if pilot is not lit when it is actually already lit?? The advantage of infrared cameras is that they can be easily used from the floor of the mechanical room, which avoids the use of catwalks and ladders. Some pilot burner consists of small filter which can be clogged after continuous operation resulting in flame failure because of carbon accumulation. The pilot light is the tiny flame inside the boiler that ignites the gas, which then consequently heats the water. With sensors, compare a reading at the diagnostic test equipment to the reading of the actual sensor. A refill will be necessary to continue operation. When your boiler flame goes out, it can be a surprising, and sometimes, frightening experience as a homeowner. Solution: Examine the flame and perform a combustion test. An example of data being processed may be a unique identifier stored in a cookie. Similar in appearance and often confused with fuel ash corrosion, high-temperature oxidation can occur locally in areas that have the highest outside diameter (OD) surface temperature relative to the oxidation limit of the tube material. Boilers and their associated systems are an important part of a modern commercial building's central energy plant. Linkages control the fuel/air mixture being fed to your boilers burner. Valve and burner issues arent things that you can test for yourself. He checked the burner, heat exchanger, etc and said everything looks good. However, lets not get too carried away. It really sounds like a problem with your air switches. Ross_7 Member Posts: 577. In most cases, an engineer will be able to clear any blockages and get your boiler functioning again.